TeSys D contactor, 4-pole (2NO+2NC), for non-inductive load applications up to 125A/1000V AC-1. It provides a 220V 50/60Hz AC coil, power connection by screw terminals, control connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (96mm width), DIN-rail mounting or screw fixing. Without build-in auxiliary contacts, side and front mounting auxiliary contact blocks available (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
range of product | TeSys D |
---|---|
product or component type | contactor |
range | TeSys |
device short name | LC1D |
[Uc] control circuit voltage | 220 V AC 50/60 Hz |
pole contact composition | 2 NO + 2 NC |
operating time | 20...35 ms closing, 6...20 ms opening |
[Ie] rated operational current | 125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit |
utilisation category | AC-1 |
[Ue] rated operational voltage | power circuit: <= 300 V DC 25...400 Hz, power circuit: <= 690 V AC |
control circuit type | AC at 50/60 Hz |
poles description | 4P |
contactor application | resistive load |
product name | TeSys D |
maximum operating rate | 3600 cyc/h 60 °C |
mechanical durability | 4 Mcycles |
product certifications | BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds register of shipping), RINA, UL |
power dissipation per pole | 12.5 W AC-1 |
average impedance | 0.8 mOhm - Ith 125 A 50 Hz for power circuit |
[Ith] conventional free air thermal current | 125 A (at 60 °C) for power circuit |
mounting support | plate, rail |
standards | CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 |
safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
rated breaking capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
Irms rated making capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
associated fuse rating | 160 A gG at <= 690 V coordination type 2 for power circuit, 200 A gG at <= 690 V coordination type 1 for power circuit |
[Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947 |
connections - terminals | control circuit: screw clamp terminals 1 cable(s) 1-2.5 mm²flexible with cable end, control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end, control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end, control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end, control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end, control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end, power circuit: connector 1 cable(s) 4-50 mm²flexible with cable end, power circuit: connector 1 cable(s) 4-50 mm²flexible without cable end, power circuit: connector 1 cable(s) 4-50 mm²solid without cable end, power circuit: connector 2 cable(s) 4-16 mm²flexible with cable end, power circuit: connector 2 cable(s) 4-25 mm²flexible without cable end, power circuit: connector 2 cable(s) 4-25 mm²solid without cable end |
tightening torque | control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm, control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2, power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm, power circuit: 12 N.m - on connector hexagonal screw head 4 mm |
electrical durability | 0.8 Mcycles 125 A AC-1 at Ue <= 440 V |
overvoltage category | III |
[Ui] rated insulation voltage | power circuit: 1000 V conforming to IEC 60947-4-1, power circuit: 600 V CSA certified, power circuit: 600 V UL certified |
[Icw] rated short-time withstand current | 135 A 40 °C - 10 min for power circuit, 320 A 40 °C - 1 min for power circuit, 640 A 40 °C - 10 s for power circuit, 990 A 40 °C - 1 s for power circuit |
protective cover | without |