TeSys D contactor - 3P - <= 440 V - 38 A AC-3 - 24...60 V AC/DC coil - LC1D38BNE

IDR2,180,000.00
In stock
SKU
LC1D38BNE
PRE ORDER
Duration Pre-Order : 30
TeSys D contactor, 3 poles (3NO), for motor control applications up to 38A/690V AC-3 (18.5kW@400V). It provides a low consumption 24-60V AC/DC coil with electronic control for direct PLC output connection, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
More Information
range of product TeSys D
product or component type contactor
range TeSys
device short name LC1D, LC1D38
[Uc] control circuit voltage 24...60 V AC 50/60 Hz, 24...60 V DC
pole contact composition 3 NO
operating time 20...90 ms opening, 45...55 ms closing
[Ie] rated operational current 38 A (at <60 °C) at <= 440 V AC-3 for power circuit, 50 A (at <60 °C) at <= 440 V AC-1 for power circuit
utilisation category AC-1, AC-3
[Ue] rated operational voltage power circuit: <= 690 V AC 25...400 Hz
control circuit type AC/DC at 50/60 Hz AC/DC electronic
poles description 3P
contactor application motor control, resistive load
product name TeSys D Green
maximum operating rate 3600 cyc/h 60 °C
mechanical durability 15 Mcycles
product certifications CCC, CSA, DNV-GL, EAC, KC, LROS (Lloyds register of shipping), UL
power dissipation per pole 3 W AC-3, 5 W AC-1
average impedance 2 mOhm - Ith 50 A 50 Hz for power circuit
auxiliary contact composition 1 NO + 1 NC
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit, 50 A (at 60 °C) for power circuit
mounting support plate, rail
standards CSA C22.2 No 60947-4-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1
safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
rated breaking capacity 550 A at 440 V for power circuit conforming to IEC 60947
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 550 A at 440 V for power circuit conforming to IEC 60947
associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at <= 690 V coordination type 1 for power circuit, 63 A gG at <= 690 V coordination type 2 for power circuit
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
connections - terminals control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end, control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end, control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid, control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end, control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end, control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid, power circuit: screw clamp terminals 1 cable(s) 1-10 mm²flexible with cable end, power circuit: screw clamp terminals 1 cable(s) 1.5-10 mm²solid, power circuit: screw clamp terminals 1 cable(s) 2.5-10 mm²flexible without cable end, power circuit: screw clamp terminals 2 cable(s) 1.5-6 mm²flexible with cable end, power circuit: screw clamp terminals 2 cable(s) 2.5-10 mm²flexible without cable end, power circuit: screw clamp terminals 2 cable(s) 2.5-10 mm²solid
tightening torque control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm, control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2, power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm, power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2
electrical durability 0.9 Mcycles 50 A AC-1 at Ue <= 440 V, 1.8 Mcycles 35 A AC-3 at Ue <= 440 V
overvoltage category III
motor power kW 18.5 kW at 380...400 V AC 50 Hz (AC-3), 18.5 kW at 415 V AC 50 Hz (AC-3), 18.5 kW at 440 V AC 50 Hz (AC-3), 18.5 kW at 500 V AC 50 Hz (AC-3), 18.5 kW at 660...690 V AC 50 Hz (AC-3), 9 kW at 220...230 V AC 50 Hz (AC-3)
motor power hp 10 hp at 200/208 V AC 60 Hz for 3 phases motors, 10 hp at 230/240 V AC 60 Hz for 3 phases motors, 2 hp at 115 V AC 60 Hz for 1 phase motors, 20 hp at 460/480 V AC 60 Hz for 3 phases motors, 25 hp at 575/600 V AC 60 Hz for 3 phases motors, 5 hp at 230/240 V AC 60 Hz for 1 phase motors
[Ui] rated insulation voltage power circuit: 690 V conforming to IEC 60947-4-1, signalling circuit: 690 V conforming to IEC 60947-1
[Icw] rated short-time withstand current 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit, 150 A 40 °C - 1 min for power circuit, 310 A 40 °C - 10 s for power circuit, 430 A 40 °C - 1 s for power circuit, 60 A 40 °C - 10 min for power circuit
protective cover with
coil type AC/DC electronic
Write Your Own Review
You're reviewing:TeSys D contactor - 3P - <= 440 V - 38 A AC-3 - 24...60 V AC/DC coil - LC1D38BNE