EasyPact EZC circuit breaker EZC100N - TMD - 40 A - 3 poles 3d - EZC100N3040

IDR816,600.00
In stock
SKU
EZC100N3040
PRE ORDER
Duration Pre-Order : 30
EasyPact EZC100N is a 3 poles fixed circuit breaker designed for the protection of low voltage electrical installations. It is used for standard applications in industries and buildings, offering good performance at competitive price The breaking capacity (Icu) is 15kA rms at 415VAC 50/60Hz. The operational voltage is 550VAC 50/60Hz or 250VDC. The rating of the thermal-magnetic trip unit is 40A. The trip unit provides fixed overload and instantaneous protections. This 3 poles version (75mm x 130mm x 60mm) comes with a variety of optional functions and accessories. Easypact EZC100N is compliant with international standards (IEC 60947, UL 508) and marine certifications.
More Information
range of product EasyPact
product or component type circuit breaker
range EasyPact
device application distribution
device short name Easypact EZC100N
trip unit name TM-D
network frequency 50/60 Hz
utilisation category category A
[Ics] rated service breaking capacity 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2, 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2, 2.5 kA at 125 V DC conforming to IEC 60947-2, 2.5 kA at 250 V DC conforming to IEC 60947-2, 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2, 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2, 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 9 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
[In] rated current 100 A at 40 °C
pollution degree 3 conforming to IEC 60664-1, 3 conforming to IEC 947-1
breaking capacity 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2, 18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2, 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2, 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2, 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2, 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2, 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ue] rated operational voltage 250 V DC conforming to IEC 60947-2, 550 V AC 50/60 Hz conforming to IEC 60947-2
suitability for isolation yes conforming to IEC 60947-2
trip unit rating 40-40 A at 50 °C
network type AC, DC
breaking capacity code N
poles description 3P
protected poles description 3t
protection type overload protection, short-circuit protection
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
product name EasyPact EZC
trip unit technology thermal-magnetic
circuit breaker name Easypact EZC100N