Variable Speed Drive (Process)
We can't find products matching the selection.
Shop By
Shopping Options
range of product
product or component type
device short name
product destination
IP degree of protection
product specific application
[Us] rated supply voltage
motor power kW
motor power hp
communication port protocol
variant
discrete input logic
EMC filter
supply frequency
option card
- communication module, BACnet MS/TP4item
- communication module, Ethernet Powerlink4item
- slot A/slot B: digital and analog I/O extension module4item
- slot A/slot B: output relay extension module4item
- slot A: communication module, CANopen daisy chain RJ454item
- slot A: communication module, CANopen screw terminals4item
- slot A: communication module, CANopen SUB-D 94item
- slot A: communication module, DeviceNet4item
- slot A: communication module, Ethernet IP/Modbus TCP/MD-Link4item
- slot A: communication module, Modbus TCP/EtherNet/IP4item
- slot A: communication module, Profibus DP V14item
- slot A: communication module, Profinet4item
prospective line Isc
line current
- 246 A at 480 V (heavy duty)1 item
- 296 A at 380 V (heavy duty)1 item
- 324 A at 480 V (normal duty)1 item
- 397 A at 380 V (normal duty)1 item
- 48.3 A at 480 V (heavy duty)1 item
- 54.8 A at 380 V (heavy duty)1 item
- 57.3 A at 480 V (normal duty)1 item
- 59 A at 480 V (heavy duty)1 item
- 66.2 A at 380 V (normal duty)1 item
- 67.1 A at 380 V (heavy duty)1 item
- 69.1 A at 480 V (normal duty)1 item
- 71.8 A at 480 V (heavy duty)1 item
- 79.8 A at 380 V (normal duty)1 item
- 81.4 A at 380 V (heavy duty)1 item
- 84.2 A at 480 V (normal duty)1 item
- 97.2 A at 380 V (normal duty)1 item
asynchronous motor control profile
output frequency
apparent power
switching frequency
maximum transient current
- 111.8 A during 60 s (heavy duty)1 item
- 116.6 A during 60 s (normal duty)1 item
- 132 A during 60 s (heavy duty)1 item
- 453 A during 60 s (heavy duty)1 item
- 470 A during 60 s (normal duty)1 item
- 82 A during 60 s (normal duty)1 item
- 92.3 A during 60 s (heavy duty)1 item
- 96.8 A during 60 s (normal duty)1 item
type of cooling
continuous output current
- 106 A at 2.5 kHz for normal duty1 item
- 302 A at 2.5 kHz for heavy duty1 item
- 427 A at 2.5 kHz for normal duty1 item
- 61.5 A at 4 kHz for heavy duty1 item
- 74.5 A at 4 kHz for heavy duty1 item
- 74.5 A at 4 kHz for normal duty1 item
- 88 A at 2.5 kHz for heavy duty1 item
- 88 A at 4 kHz for normal duty1 item
nominal switching frequency
degree of protection
speed drive output frequency
safety function
synchronous motor control profile
My Wish List