Search results for: 'easycan capacity 20 24 kvar 400 v 50 60'
Shop By
Now Shopping by
Shopping Options
- mounting support plate Remove This Item
- motor power hp 20 hp at 200/208 V AC 50/60 Hz for 3 phases motors Remove This Item
range of product
product or component type
range
device short name
[Uc] control circuit voltage
pole contact composition
operating time
[Ie] rated operational current
poles description
[Ith] conventional free air thermal current
product name
overvoltage category
standards
[Ue] rated operational voltage
control circuit type
contactor application
maximum operating rate
mechanical durability
product certifications
power dissipation per pole
average impedance
auxiliary contact composition
safety reliability level
rated breaking capacity
Irms rated making capacity
associated fuse rating
[Uimp] rated impulse withstand voltage
connections - terminals
- control circuit: screw clamp terminals 1 cable(s) 1-2.5 mm²flexible with cable end2item
- control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end2item
- control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end4item
- control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end4item
- control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end4item
- control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end4item
- control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end4item
- power circuit: connector 1 cable(s) 4-50 mm²flexible with cable end2item
- power circuit: connector 1 cable(s) 4-50 mm²flexible without cable end2item
- power circuit: connector 1 cable(s) 4-50 mm²solid without cable end2item
- power circuit: connector 2 cable(s) 4-16 mm²flexible with cable end2item
- power circuit: connector 2 cable(s) 4-25 mm²flexible without cable end2item
- power circuit: connector 2 cable(s) 4-25 mm²solid without cable end2item
- power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²flexible with cable end1 item
- power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²flexible without cable end1 item
- power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²solid without cable end1 item
- power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²flexible with cable end1 item
- power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²flexible without cable end1 item
- power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²solid without cable end1 item
- power circuit: screw connection 1 cable(s) 1-35 mm²flexible with cable end1 item
- power circuit: screw connection 1 cable(s) 1-35 mm²flexible without cable end1 item
- power circuit: screw connection 1 cable(s) 1-35 mm²solid without cable end1 item
- power circuit: screw connection 2 cable(s) 1-25 mm²flexible with cable end1 item
- power circuit: screw connection 2 cable(s) 1-25 mm²flexible without cable end1 item
- power circuit: screw connection 2 cable(s) 1-25 mm²solid without cable end1 item
tightening torque
- control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm2item
- control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 22item
- control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm2item
- control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 22item
- power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm2item
- power circuit: 12 N.m - on connector hexagonal screw head 4 mm2item
- power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1-25 mm² hexagonal screw head 4 mm2item
- power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25-35 mm² hexagonal screw head 4 mm2item
electrical durability
motor power kW
- 11 kW at 400 V AC 50/60 Hz (AC-4)2item
- 15 kW at 400 V AC 50/60 Hz (AC-4)2item
- 18.5 kW at 220...230 V AC 50/60 Hz (AC-3)2item
- 22 kW at 220...230 V AC 50/60 Hz (AC-3)2item
- 30 kW at 380...400 V AC 50/60 Hz (AC-3)2item
- 37 kW at 380...400 V AC 50/60 Hz (AC-3)2item
- 37 kW at 500 V AC 50/60 Hz (AC-3)2item
- 37 kW at 660...690 V AC 50/60 Hz (AC-3)2item
- 45 kW at 1000 V AC 50/60 Hz (AC-3)2item
- 45 kW at 415...440 V AC 50/60 Hz (AC-3)2item
- 45 kW at 660...690 V AC 50/60 Hz (AC-3)2item
- 55 kW at 500 V AC 50/60 Hz (AC-3)2item
[Ui] rated insulation voltage
- power circuit: 1000 V conforming to IEC 60947-4-12item
- power circuit: 600 V CSA certified4item
- power circuit: 600 V UL certified4item
- power circuit: 690 V conforming to IEC 60947-4-12item
- signalling circuit: 600 V CSA certified4item
- signalling circuit: 600 V UL certified4item
- signalling circuit: 690 V conforming to IEC 60947-14item
[Icw] rated short-time withstand current
- 100 A - 1 s for signalling circuit4item
- 110 A 40 °C - 10 min for power circuit2item
- 120 A - 500 ms for signalling circuit4item
- 135 A 40 °C - 10 min for power circuit2item
- 140 A - 100 ms for signalling circuit4item
- 260 A 40 °C - 1 min for power circuit2item
- 320 A 40 °C - 1 min for power circuit2item
- 520 A 40 °C - 10 s for power circuit2item
- 640 A 40 °C - 10 s for power circuit2item
- 900 A 40 °C - 1 s for power circuit2item
- 990 A 40 °C - 1 s for power circuit2item
protective cover
My Wish List