Search results for: 'easycan capacity 20 24 kvar 400 v 50 60'
Shop By
Now Shopping by
Shopping Options
- maximum operating rate 2400 cyc/h 60 °C Remove This Item
- mounting support plate Remove This Item
range of product
product or component type
range
device short name
[Uc] control circuit voltage
pole contact composition
operating time
[Ie] rated operational current
poles description
[Ith] conventional free air thermal current
product name
overvoltage category
standards
utilisation category
[Ue] rated operational voltage
control circuit type
contactor application
mechanical durability
product certifications
power dissipation per pole
average impedance
auxiliary contact composition
safety reliability level
rated breaking capacity
Irms rated making capacity
associated fuse rating
[Uimp] rated impulse withstand voltage
connections - terminals
- control circuit: screw clamp terminals 1 cable(s) 1-2.5 mm²flexible with cable end1 item
- control circuit: screw clamp terminals 1 cable(s) 1-2.5 mm²flexible without cable end1 item
- control circuit: screw clamp terminals 1 cable(s) 1-2.5 mm²solid without cable end1 item
- control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end1 item
- control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible without cable end1 item
- control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²solid without cable end1 item
- power circuit: connector 1 cable(s) 10-120 mm²flexible with cable end1 item
- power circuit: connector 1 cable(s) 10-120 mm²flexible without cable end1 item
- power circuit: connector 1 cable(s) 10-120 mm²solid without cable end1 item
- power circuit: connector 2 cable(s) 10-50 mm²flexible with cable end1 item
- power circuit: connector 2 cable(s) 10-50 mm²flexible without cable end1 item
- power circuit: connector 2 cable(s) 10-50 mm²solid without cable end1 item
tightening torque
electrical durability
motor power kW
- 18.5 kW at 400 V AC 50/60 Hz (AC-4)1 item
- 30 kW at 220...230 V AC 50/60 Hz (AC-3)1 item
- 55 kW at 380...400 V AC 50/60 Hz (AC-3)1 item
- 59 kW at 415...440 V AC 50/60 Hz (AC-3)1 item
- 65 kW at 1000 V AC 50/60 Hz (AC-3)1 item
- 75 kW at 500 V AC 50/60 Hz (AC-3)1 item
- 80 kW at 660...690 V AC 50/60 Hz (AC-3)1 item
motor power hp
[Ui] rated insulation voltage
[Icw] rated short-time withstand current
- 100 A - 1 s for signalling circuit1 item
- 1100 A 40 °C - 1 s for power circuit1 item
- 120 A - 500 ms for signalling circuit1 item
- 140 A - 100 ms for signalling circuit1 item
- 250 A 40 °C - 10 min for power circuit1 item
- 550 A 40 °C - 1 min for power circuit1 item
- 950 A 40 °C - 10 s for power circuit1 item
protective cover
My Wish List