- [In] rated current 250 A at 40 °C Remove This Item
- trip unit rating 250-250 A at 50 °C Remove This Item
range of product
product or component type
range
device application
device short name
trip unit name
network frequency
product name
utilisation category
[Ue] rated operational voltage
[Uimp] rated impulse withstand voltage
[Ui] rated insulation voltage
[Ics] rated service breaking capacity
- 10 kA at 125 V DC conforming to IEC 60947-21 item
- 10 kA at 250 V DC conforming to IEC 60947-21 item
- 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-21 item
- 12.5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-21 item
- 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-22item
- 15 kA at 125 V DC conforming to IEC 60947-22item
- 15 kA at 250 V DC conforming to IEC 60947-22item
- 18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-21 item
- 18 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-21 item
- 18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-21 item
- 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-21 item
- 4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-21 item
- 42.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-21 item
- 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-21 item
- 42.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-21 item
- 5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-22item
suitability for isolation
protection type
breaking capacity
- 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-22item
- 20 kA Icu at 125 V DC 1P conforming to IEC 60947-21 item
- 20 kA Icu at 250 V DC 2P conforming to IEC 60947-21 item
- 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-21 item
- 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-21 item
- 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-22item
- 30 kA Icu at 125 V DC 1P conforming to IEC 60947-22item
- 30 kA Icu at 250 V DC 2P conforming to IEC 60947-22item
- 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-21 item
- 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-21 item
- 36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-21 item
- 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-21 item
- 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-21 item
- 85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-21 item
- 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-22item
trip unit technology
pollution degree
protected poles description
circuit breaker name