Search results for: 'vacuum circuit brake'
- Did you mean
- vacuum circuit breaker
- vacuum circuit break
- Related search terms
- vacuum circuit break
- vacuum circuit base
- vacuum circuit blank
- vacuum circuit black
- vacuum circuit block
Shop By
Now Shopping by
Shopping Options
- Category HOME_RECOMENDATION_PRODUCT Remove This Item
range of product
product or component type
device application
device short name
[Uc] control circuit voltage
pole contact composition
operating time
trip unit name
[Ie] rated operational current
[Ith] conventional free air thermal current
type of operator
network frequency
contacts type and composition
contact operation
head type
[In] rated current
[Us] rated supply voltage
sale per indivisible quantity
overvoltage category
standards
utilisation category
[Ue] rated operational voltage
control circuit type
contactor application
maximum operating rate
mechanical durability
product certifications
power dissipation per pole
average impedance
auxiliary contact composition
mounting support
safety reliability level
rated breaking capacity
Irms rated making capacity
associated fuse rating
[Uimp] rated impulse withstand voltage
connections - terminals
- control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end1 item
- control circuit: screw clamp terminals 1 cable(s) 1-4 mm²flexible without cable end1 item
- control circuit: screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end1 item
- control circuit: screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end1 item
- control circuit: screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end1 item
- control circuit: screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end1 item
- power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²flexible with cable end1 item
- power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²flexible without cable end1 item
- power circuit: EverLink BTR screw connectors 1 cable(s) 1-35 mm²solid without cable end1 item
- power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²flexible with cable end1 item
- power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²flexible without cable end1 item
- power circuit: EverLink BTR screw connectors 2 cable(s) 1-25 mm²solid without cable end1 item
- screw clamp terminals, 1 x 0.22...2 x 2.5 mm² without cable end conforming to EN/IEC 60947-11 item
- screw clamp terminals, 2item
- screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to EN/IEC 60947-11 item
tightening torque
- control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm1 item
- control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 21 item
- power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1-25 mm² hexagonal screw head 4 mm1 item
- power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25-35 mm² hexagonal screw head 4 mm1 item
electrical durability
motor power kW
motor power hp
- 15 hp at 200/208 V AC 50/60 Hz for 3 phases motors1 item
- 15 hp at 230/240 V AC 50/60 Hz for 3 phases motors1 item
- 3 hp at 115 V AC 50/60 Hz for 1 phase motors1 item
- 40 hp at 460/480 V AC 50/60 Hz for 3 phases motors1 item
- 40 hp at 575/600 V AC 50/60 Hz for 3 phases motors1 item
- 7.5 hp at 230/240 V AC 50/60 Hz for 1 phase motors1 item
[Ui] rated insulation voltage
- 690 V AC 50/60 Hz conforming to IEC 60947-21 item
- power circuit: 600 V CSA certified1 item
- power circuit: 600 V UL certified1 item
- power circuit: 690 V conforming to IEC 60947-4-11 item
- signalling circuit: 600 V CSA certified1 item
- signalling circuit: 600 V UL certified1 item
- signalling circuit: 690 V conforming to IEC 60947-11 item
[Icw] rated short-time withstand current
- 100 A - 1 s for signalling circuit1 item
- 120 A - 500 ms for signalling circuit1 item
- 140 A - 100 ms for signalling circuit1 item
- 208 A 40 °C - 1 min for power circuit1 item
- 400 A 40 °C - 10 s for power circuit1 item
- 810 A 40 °C - 1 s for power circuit1 item
- 84 A 40 °C - 10 min for power circuit1 item
protective cover
[Ics] rated service breaking capacity
- 1.25 kA at 380 V AC 50/60 Hz conforming to IEC 60947-21 item
- 1.25 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-21 item
- 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-21 item
- 2.5 kA at 125 V DC conforming to IEC 60947-21 item
- 9 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-21 item
suitability for isolation
protection type
operator profile
curve code
number of protected poles
breaking capacity
- 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-21 item
- 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-11 item
- 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-21 item
- 15 kA Icu at 1 item
- 18 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-21 item
- 2.5 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-21 item
- 2.5 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-21 item
- 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-21 item
- 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-21 item
- 42 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-21 item
- 42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-21 item
- 5 kA Icu at 125 V DC 1P conforming to IEC 60947-21 item
trip unit technology
pollution degree
trip unit rating
protected poles description
circuit breaker name
transmission support medium
communication service
connectivity to devices
maximum supply current
web services
connected auxiliaries
operator additional information
bezel material
light source
mounting diameter
shape of signaling unit head
fixing collar material
bulb base
cap/operator or lens colour
operator position information
My Wish List